Designing a test heat exchanger

Technical resources

As the physical layout of the exchanger cannot be determined until the area is known the design of an exchanger is of necessity a trial and error procedure. The steps in a typical design procedure are given below:
  1. Define the duty: heat transfer rate, fluid flow-rates, temperatures.
  2. Collect together the fluid physical properties required: density, viscosity, thermal conductivity.
  3. Decide on the type of exchanger to be used.
  4. Select a value for the overall coefficient, U.
  5. Calculate the mean temperature difference, Δtm .
  6. Calculate the area required from equation Q = UA Δtm
  7. Decide the exchanger layout.
  8. Calculate the individual coefficients.
  9. Calculate the U and compare it with selected U value. If the calculated value differs significantly then return to step 6.
  10. Optimize the design: repeat steps 4 to 10, as necessary, to determine the cheapest exchanger that will satisfy the duty. Usually that will be one with the smallest area.
Typical values of the overall heat-transfer coefficient for various types of heat exchanger are given below:

Shell and tube exchangers

Hot fluid Cold fluid U (W/m2  oC)
Heat exchangers
Water Water 800-1500
Steam Water 1500-4000
Coolers
Organic solvents Water 250-750
Light oils Water 350-900
Heavy oils Water 60-300
Gases Water 20-300
Condensers
Aqueous vapors Water 1000-1500
Organic vapors Water 700-1500
Organics (some non-condensables) Water 500-700
Vacuum condensers Water 200-500
Jacketed vessels
Water Dilute aqueous sol. 200-500
Water Light organics 200-300